Equipment ImageModelCountry of originDescriptionBrochure/Manual
rental-01Omicron CPC 100 with CP TD1AustriaKey Features: - Up to 800 A or 2000 V with up to 5 kVA over a frequency range of 15 Hz - 400 Hz or 400 A DC - Excellent interference suppression facilitates measurement of small signals - Easy to transport (just 29 kg) – ideal for on-site testing - Testing templates, automatically generated testing procedures and test reports - Up to 2000 A or 12 kV/ 15kV through use of current or voltage amplifiers
Application: - Current transformers (CT) - Voltage transformers (VT) - Transformers - Rotating machines - Grounding systems - Lines and cables - Circuit breakers
2-CMC356Omicron CMC 356AustriaThe CMC 356 is the universal solution for testing all generations and types of protection relays. Its powerful six current sources (three-phase mode: up to 64 A / 860 VA per channel) with a great dynamic range, make the unit capable of testing even high-burden electromechanical relays with very high power demands. The CMC 356 is the first choice for applications requiring the highest versatility, amplitude and power. Commissioning engineers will particularly appreciate its ability to perform wiring and plausibility checks of current transformers, by using primary injection of high currents from the test set.
3-CMC256Omicron CMC 256AustriaThe CMC 256plus is the first choice for applications requiring very high accuracy. This unit is not only an excellent test set for protection devices of all kinds but also a universal calibrator. Its high precision allows the calibration of a wide range of measuring devices, including: energy meters of class 0.2, measuring transducers, power quality measurement devices and phasor measurement units (PMU). Its unique accuracy and flexibility make the CMC 256plus ideal for protection and measurement equipment manufacturers for research and development, production and type testing.
4-DLRO200CRM (Megger DLRO200)UKMegger Ducter™ DLRO200 measures resistances between 0.1 µΩ and 1 Ω, at high currents. This versatile instrument can provide test currents from 10 amps up to 200 amps subject to the load resistance and supply voltage. A large LCD displays all all test parameters and measurement results.
5-TimingCB Analyzer (SCOPE SCOT M3K)IndiaSCOT series of CB Time Interval Meters from SCOPE are compact and reliable instruments to measure operating time of all types of HV/EHV circuit breakers under charged switchyard conditions up to 400kV. SCOT M3K measures and displays CLOSE, OPEN and CLOSE-OPEN time of main contacts of 3 poles connected end to end, simultaneously.
6-IR-3125AInsulation Tester (Kyoritsu 3125A)Japan• Insulation Resistance up to 1TΩ • Short-Circuit Current up to 1.5mA • Wide Test Voltage from 250V to 5000V • Diagnosis Function of PI and DAR • Newly-designed alligator clip • It comes with a tough hard case • Filter function reduces noise interference for obtaining stable measurement • Large display with Bar Graph indication and backlight • Live voltage warning • Safety standard IEC 61010-1 CAT IV 300V / CAT III 600V
7-P400-5Primary InjectorBangladeshPrimary current injector is used for checking CT circuit. It is also essential for checking circuit breakers tripping at the rated current.|Our primary injector can inject up to 1200 A.
8-Fluke-1623Earth Resistivity Tester (Fluke 1623-2)USAThe Fluke 1623-2 is a unique earth ground tester that can perform all four types of earth ground measurement. ? 3- and 4-Pole Fall-of-Potential (using stakes) ? 4-Pole Soil Resistivity Testing (using stakes) ? Selective Testing (using 1 clamp and stakes) ? Stakeless Testing (using 2 clamps only)
9-KEW-4105AEarth Resistance Tester (Kyoritsu KEW-4105A)Japan• In addition to the facility for precision measurement, test leads for simplified two wire measuring system also supplied as standard accessories. (unit can be hung from the neck for simplified measurement) • The latest circuit design permits the instrument to operate with the minimum of influence from earth voltage and earth resistance of auxiliary earth spikes. • Dust and drip proof. (designed to IEC 60529 IP54) • Earth resistance value can be read directly from the scale. • Designed to meet IEC 61010-1 safety standard. • Capable of measuring earth voltage. • Small and lightweight. Shock resistant new case material. • 2mA measuring current permits earth resistance tests without tripping earth leakage current breakers in the circuit under test.
10-Uni-T-UT261BPhase Sequence Meter (UNI-T UT261B)ChinaUT261B Phase Sequence and Motor Rotation Indicator (hereinafter referred to be as UT261B) is a handheld battery powered instrument, widely used to identify phase orientation of three-phase industrial equipment and motor rotation direction.
11-hzjq-1-transformer-oil-bdv-test-kit-80kvOil Breakdown Voltage (Huazheng HZJQ-1BChinaMany power systems, railway systems, large-scale petrochemical plants and enterprises have a lot of electrical equipment whose internal insulation are mostly oil-filled insulation type, and therefore, test on insulating oil dielectric strength is common and necessary. To meet the needs of the market, we have developed and produced a series of insulating oil dielectric strength testers according to national standard GB/T507-2002, industry standard DL429.9-91 and the latest Electric Power Industry Standard DL/T846.7-2004 by ourselves. This instrument, by using a single-chip microcomputer as the core, can operate in full automation with high accuracy, greatly improving work efficiency and reducing the labor intensity of workers. Moreover, it is small in size and convenient to carry.
12-Centrifuge-double-stage-vacuum-transformer-oilOil Filtration KitChinaOil degradation is a wide-spread problem in industries using oil-filled transformer equipment. There are many causes of the degrading or aging of industrial oil The oil is drawn from the lowest port of the oil tank and enters the machine, into the first filter housing that retains all the contaminants. The clean oil is heated and enters the vacuum column filled with Raschig rings to create a larger area for oil to spread to achieve space separation of water vapor and gases. A column of Raschig rings extend the travel period of the oil flow in the vacuum system to obtain the best outcome in one pass. The vapor and gas are then removed by the vacuum pump. The cleaned and dry oil passes through a final filtration in a second filter housing before returning to transformer.
13-Hi-POtHi pot (Kvtester ZC-501B)ChinaThe test also called transformer booster, it is the basic equipment for power station, power supply system and scientific research units. Used for the dielectric strength test of various electrical appliances, electrical equipment, insulation materials in the prescribed voltage, test products insulation level, it is found that the insulation defects sample measure to bear voltage capability.
14-rentalHi pot (REK RK2671AM)ChinaThe RK2671AM withstand voltage tester of Meiruike is the measurement instrument for compressive strength. It is mainly used for insulation leakage safety test of product. It can test the electrical safety performance index of breakdown voltage, current of which all kind of the measured object intuitive, accurate & fast and can be used for testing the components and overall performance as a high voltage source.
15-Dilo-Type3-027SF6 Gas Analyzer (DILO Type 3-027)GermanyThe DILO 3-027-R002 SF6 Volume Percentage Measuring Device measures the gas purity necessary to maintain the dielectric property for arc quenching in circuit breakers. The speed-of-sound measurement generates results immediately. Key Features: ? Easy handling and rinsing after measurements ? Use for another gas compartment immediately ? Independent of air pressure and its position ? Response time is approximately one minute ? Digital indication of the measuring values
16-UT620ADigital Micro Ohm Meter (UNI-T UT620A)ChinaUT620A is used to measure DC low resistance through 4-wire method. Its features are: Comparison function to determine if the device is in good condition, unknown wire length calculation (FT/M); two-way data transmission by USB interface. UT620A can be used in narrow space for on-site troubleshooting, such as metal coating resistance, motor and small transformer winding resistance, welding points, power distribution cabinet bus, lead connection inspections, and more.
17-HZ-3110B-10a-automatic-transformer-winding-resistanceTransformer Turn Ratio Tester (Huazheng HZBB-10B)China Huazheng Electric HZBB-10B Intelligent Tester of Transformer Ratio and Connection Groups adopts popular ARM processor, 168M frequency, 128M memory available to be extended to 4G memory card. The LCD screen adopts 5-inch high-definition color touch screen, combined with emwin display, making the tester interface simple and user-friendly in full touch screen and non-keyboard operation. The tester supports database and can be exported from the USB drive or through the data cable to the background computer. Elaborate and compact design, unique thinking, makes the tester superior and powerful with small size and light weight. The tester uses a programmable signal source, can output single-phase, two-phase or three-phase standard Sine signal or high-frequency Sine signal, with adjustable output phase frequency. The tester adopts the new algorithm developed by our company to measure the ratio of three-phase transformer and ensure the measurement accuracy without adjusting the balance of the three-phase power supply. Therefore, the transformer ratio and wiring method can be measured in about 3 seconds.
18-hzbb-10b-3-phase-transformer-turns-raio-meterTransformer DC Resistance Tester (Huazheng HZ-3110B)ChinaThe Huazheng Electric DC resistance is the transformer’s semi-finished product, finished product test, installation, commissioning test, and electric part prevention test necessary test project. The transformer coil can effectively find the device welding, connecting parts loose, missing unit, disconnection, and other manufacturing default and other hidden danger occurred after operation. The DC Resistance transformer to meet fast measurement requirement, we developed HZ-3110B DC Resistance Tester. The instrument is a new powerful technology, small size, light weight, high output current and other characteristics. The device is controlled by the microcontroller, with a high degree of automation, automatic discharge functions. It is a test instrument of high precision, simple, direct way to achieve fast transformer measurement.
19-Dilo-Mirror-Analyser-SF6-3-035R-RSF6 Gas Dew Point Meter (DILO)GermanyThe SF6 Mirror-Analyzer works by utilizing the dew point principle, the cooling of a volume of gas until condensation forms, to measure moisture content. As the gas sample passes over the chilled mirror surface, the moisture content of the gas is determined by comparing the temperature of the mirror to the condensation rate of the gas. The chilled mirror technology allows for highly accurate results over a wide range of dew points. The other parameters of SF6 quality are determined by measuring the speed of sound (SF6 volume percentage) and electrochemical reaction (SO2 concentration).